logo

Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582

Guangzhou Xingjin Fire Equipment Co.,Ltd. Profiel van het bedrijf
producten
Thuis > producten > FM200 cilinder > Modular Cabinet FM200 Cylinder with 40-300 kg Filling Capacity 2.5 MPa Storage Pressure and <10s Jet Time for Automatic Fire Protection

Modular Cabinet FM200 Cylinder with 40-300 kg Filling Capacity 2.5 MPa Storage Pressure and <10s Jet Time for Automatic Fire Protection

Productgegevens

Plaats van herkomst: Guangzhou, China

Merknaam: XINGJIN

Certificering: CCC,CAC,ROHS

Modelnummer: GQQ40/GQQ70/GQQ90/GQQ100etc

Betaling en verzendvoorwaarden

Min. bestelaantal: 10 sets systeem

Prijs: Pricing based on quantity

Verpakking Details: Houten doos of multiplex buitenkast met bellentas of papier

Levertijd: 15-20 dagen

Betalingscondities: T/T, L/C

Levering vermogen: 30000et/maand

Vind de beste prijs
Productgegevens
Markeren:

40-300 kg Filling Capacity FM200 Cylinder

,

2.5 MPa Storage Pressure FM200 Cylinder

,

<10s Jet Time Cabinet-Type Fire Extinguishing System

Maximale vulcapaciteit (kg):
40 tot 300
Opslagdruk bij 20℃ (MPa):
2.5
Jettijd(en):
<10
Werkende Temperatuur (°C):
0~50
Externe afmetingen: lengte, breedte en hoogte (mm):
500×450×1450;550×550×1900;600×550×2150...
Maximale vulcapaciteit (kg):
40 tot 300
Opslagdruk bij 20℃ (MPa):
2.5
Jettijd(en):
<10
Werkende Temperatuur (°C):
0~50
Externe afmetingen: lengte, breedte en hoogte (mm):
500×450×1450;550×550×1900;600×550×2150...
Productbeschrijving

Product Introduction:
  Heptafluoropropane fire extinguishing products are highly mature fire extinguishing products in the gas fire protection market. They have stable fire extinguishing performance and can quickly put out Class A, B, C, E fires and electrical fires. They are especially effective in protecting electronic circuit equipment, precious metal items, cultural relics and archival materials. The evaporation of heptafluoropropane in the atmosphere will not cause pollution to equipment and the environment and will not damage the ozone layer.

Structural Features:
This cabinet-type fire extinguishing system integrates an extinguishing agent storage container assembly, high-pressure hose, nozzle, and electromagnetic drive device. Connected to an automatic fire alarm controller, it enables automatic detection and extinguishing of fires. Because the extinguishing agent storage cylinders are housed within the cabinet, different volumes of single cylinders can be used to protect small protected areas of varying sizes, reducing the floor space required. The multi-hole nozzles ensure rapid and even filling of the entire protected area with the extinguishing agent. Similar to suspended fire extinguishing systems, it features simple installation and low project investment.

Modular Cabinet FM200 Cylinder with 40-300 kg Filling Capacity 2.5 MPa Storage Pressure and <10s Jet Time for Automatic Fire Protection 0 Modular Cabinet FM200 Cylinder with 40-300 kg Filling Capacity 2.5 MPa Storage Pressure and <10s Jet Time for Automatic Fire Protection 1


Performance parameters of cabinet-type HFC-227ea fire extinguishing device:
 

Specifications and Models

Maximum filling capacity (kg) Storage pressure
at 20℃ (MPa)
Jet time (s) Operating temperature (°C) External dimensions:
Length, width, and height (mm)
GQQ40/ 2.5 40 2.5 <10 0~50 500×450×1450
GQQ70/ 2.5 70 2.5 <10 0~50 500×450×1450
GQQ90/ 2.5 90 2.5 <10 0~50 500×450×1650
GQQ100/ 2.5 100 2.5 <10 0~50 500×450×1650
GQQ120/ 2.5 120 2.5 <10 0~50 550×550×1900
GQQ150/ 2.5 150 2.5 <10 0~50 550×550×1900
GQQ180/ 2.5 180 2.5 <10 0~50 600×550×2150
GQQ70×2/ 2.5 140 2.5 <10 0~50 1100×450×1450
GQQ90×2/ 2.5 180 2.5 <10 0~50 1100×450×1650
GQQ100×2/ 2.5 200 2.5 <10 0~50 1100×450×1650
GQQ120×2/ 2.5 240 2.5 <10 0~50 1100×550×1900
GQQ150×2/ 2.5 300 2.5 <10 0~50 1100×550×1900

 
Working Principle:
The cabinet-type heptafluoropropane fire extinguishing device produced by our company uses an electromagnetic valve as the driving device, ensuring reliable start-up performance. When the fire detector receives a fire alarm signal from the protected area, the alarm controller outputs a DC24V 1.5A voltage, causing the electromagnetic valve to activate and open the extinguishing agent storage cylinder valve. The heptafluoropropane extinguishing agent is then sprayed into the protected area through the connecting hose and nozzle to extinguish the fire.
Modular Cabinet FM200 Cylinder with 40-300 kg Filling Capacity 2.5 MPa Storage Pressure and <10s Jet Time for Automatic Fire Protection 2
 

Packaging and transportation :
Packaging:
The Cabinet-type fire extinguishing will be carefully packaged to ensure safe delivery and handling. The packaging will include the following materials: heavy-duty cardboard boxes, foam packaging, protective foam, and instructions

Transportation:
We offer global shipping for our Cabinet-type fire extinguishing. The following transportation methods are available for selection:
All goods will be sent using reliable and trustworthy express delivery services to ensure timely and safe delivery. Once their order is dispatched, the customer will receive a tracking number via email.

Special handling instructions:
If your goods have any special handling instructions, please contact us at least 24 hours before your order is dispatched. We will do our best to meet your requirements.
Modular Cabinet FM200 Cylinder with 40-300 kg Filling Capacity 2.5 MPa Storage Pressure and <10s Jet Time for Automatic Fire Protection 3
Why choose us?
Modular Cabinet FM200 Cylinder with 40-300 kg Filling Capacity 2.5 MPa Storage Pressure and <10s Jet Time for Automatic Fire Protection 4